DAD4841, DAD4941, overlying - AP600 mm, common cutout, Installation drawings
① Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., ② Exhaust duct Ø 150 mm.
Downdraft extractor system in an elegant obsidian black design and with intuitive SmartControl operation
DAD4841, DAD4941, overlying - AP600 mm, common cutout, Installation drawings
① Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., ② Exhaust duct Ø 150 mm.
DAD4841, DAD4941, flush - AP600 mm, Side view, Installation drawings
① Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., ② Exhaust duct Ø 150 mm.
DAD4841, DAD4941, surface mounted installation, common cutout, Installation drawings
Side-by-side installation of the downdraft hood and the cooktop in a common cutout., Example: combination with KM 7684 FL or KM 7689 FL., Surface mounted installation, 1) Cut-out for exhaust air line in cabinet base., 2) Ensure sufficient stability of the worktop., , Exhaust air connection ø150 mm.
DAD4841, DAD4941, surface mounted installation, common cutout, Installation drawings
Side-by-side installation of the downdraft hood and the cooktop in a common cutout., Example: combination with KM 7697 FL or KM 7594 FL., Surface-mounted installation, 1) Cut-out for exhaust air line in cabinet base., 2) Ensure sufficient stability of the worktop., , Exhaust air connection ø150 mm.
DAD4841, DAD4941, Installation drawings
① The minimum dimension is required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used.
DAD4841, DAD4941, flush, Installation drawings
Side-by-side installation of the downdraft hood and the cooktop in a common cutout., Example: combination with KM 7697 FL or KM 7594 FL., Flush installation, 1) Cut-out for exhaust air duct in the cabinet base., 2) Ensure sufficient stability of the worktop., 3) Step milling for flush mounting in a worktop. Note the, the different milling widths for the hob and the downdraft. , Instead of a step milling, a 5.5 mm downwardly offset wooden strip can be installed (not included in the scope of delivery)., , Exhaust air connection ø 150 mm.
DAD4841, DAD4941, overlying, Installation drawings
Installation of the downdraft hood and cooktop in separate cutouts., Surface-mounted installation, 1) Cutout for exhaust air line in cabinet base., 2) Ensure sufficient stability of the worktop., Exhaust air connection ø150 mm
DAD4841, DAD4941, Installation drawings
DAD4840, DAD4940, DAD4841, DAD4941 - flush - side view - Installation drawings
① Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., ② Exhaust air connection Ø 150 millimetres.
DAD4840, DAD4940, DAD4841, DAD4941 - surface mounted, AP
① Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., ② Exhaust air connection Ø 150 millimetres.
DAD4841, DAD4941, flush, Installation drawings
Side-by-side installation of the downdraft hood and the cooktop in a common cutout., Example: combination with KM 7697 FL or KM 7594 FL., Flush installation, 1) Cut-out for exhaust air duct in the cabinet base., 2) Ensure sufficient stability of the worktop., 3) Step milling for flush mounting in a worktop. Note the, the different milling widths for the hob and the downdraft. , Instead of a step milling, a 5.5 mm downwardly offset wooden strip can be installed (not included in the scope of delivery)., , Exhaust air connection ø 150 mm.
DAD4840, DAD4940, DAD4841, DAD4941 - surface mounted, AP
① Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., ② Exhaust air connection Ø 150 millimetres.
DAD4841, Installation drawings
1. Stepped cutout for flush-fit installation in stone worktops (granite, marble)., 2. Ensure that materials are sufficiently stable., 3. Cut-out off-centre., Exhaust duct Ø 150 mm., * Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used.
DAD4841, DAD4941, flush - AP600 mm, common cutout, Installation drawings
① Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., ② Exhaust duct Ø 150 mm.
DAD4841, DAD4941, overlying - AP600 mm, Side view, Installation drawings
① Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., ② Exhaust duct Ø 150 mm.
DAD4841, DAD4941, flush, Installation drawings
Installation of the downdraft hood and cooktop in separate cutouts., Flush installation., 1) Cut-out for exhaust air duct in the cabinet base., 2) Ensure sufficient stability of the worktop., 3) Step milling for flush mounting in a countertop. Note the, the different milling widths for the hob and the downdraft. Instead of a step milling, a wooden strip offset 5.5 mm downwards can be installed as an alternative (not included in the scope of delivery)., , Exhaust air connection ø 150 mm.
DAD4840, DAD4940, DAD4841, DAD4941 - flush - side view - Installation drawings
① Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., ② Exhaust air connection Ø 150 millimetres.