DAD 4841 Black Levantar - Downdraft extractor system
   

DAD 4841 Black Levantar
Downdraft extractor system in an elegant obsidian black design and with intuitive SmartControl operation

Price: AED 15,900 
Article color:  
  • Obsidian black
DAD4841 Black Levantar

More product information

Downdraft extractor system in an elegant obsidian black design and with intuitive SmartControl operation


  • 916 mm wide – the perfect combination with panorama hobs 

    Combination with panorama hobs

    Depending on availability can be perfectly combined with KM 7684 FL or KM 7689 FL.
  • Easy recirculation mode installation with plug&play accessory set

    Plug&Play accessory set 

    DUP 150: with the Plug&Play accessory set for recirculation, planning and installation are quick and easy without a separate ducting system and additional plinth box. 
  • Motorised retractable deflector plate – Hood in Motion

    Hood in motion

    Best possible ergonomics: The cooker hood canopy automatically moves to the ideal working position.
  • Unique user convenience – Con@ctivity

    Con@ctivity

    Innovative convenience: the cooker hood reacts automatically to settings on the hob.
  • Efficient filtration- 10-ply stainless-steel grease filter

    Stainless steel grease filters (10-layer)

    Looks great and does a good job: effective grease filtering and easy cleaning in a dishwasher.

Downloads - DAD 4841 Black Levantar

User manual & Assembly

Description Format Download
Assembly planpdf Download
Assembly planpdf Download
Operating instructions accessoriespdf Download
Product Sheetpdf Download

CAD data / BIM data

Description Format Download
3D data RVTzip Download
3D data FBXzip Download
3D data RFAzip Download
3D data IFCzip Download
3D data DWGzip Download

Installation drawings

Installation drawings

Whether you want to replace a household appliance or planning a kitchen - here you will find all the relevant installation diagrams for your Miele appliance.

If you want to download an installation diagram, please click on the appropriate image and the high-resolution version is displayed. To download, click the right mouse button and save the image on your computer.

Please note that the installation and maintenance of our equipment should only be performed by a licensed contractor. For questions, please call us and we will advise you without any obligation!

explanations

DAD4841, DAD4941, overlying - AP600 mm, common cutout, Installation drawings

① Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., ② Exhaust duct Ø 150 mm.

explanations

DAD4841, DAD4941, flush - AP600 mm, Side view, Installation drawings

① Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., ② Exhaust duct Ø 150 mm.

explanations

DAD4841, DAD4941, surface mounted installation, common cutout, Installation drawings

Side-by-side installation of the downdraft hood and the cooktop in a common cutout., Example: combination with KM 7684 FL or KM 7689 FL., Surface mounted installation, 1) Cut-out for exhaust air line in cabinet base., 2) Ensure sufficient stability of the worktop., , Exhaust air connection ø150 mm.

explanations

DAD4841, DAD4941, surface mounted installation, common cutout, Installation drawings

Side-by-side installation of the downdraft hood and the cooktop in a common cutout., Example: combination with KM 7697 FL or KM 7594 FL., Surface-mounted installation, 1) Cut-out for exhaust air line in cabinet base., 2) Ensure sufficient stability of the worktop., , Exhaust air connection ø150 mm.

explanations

DAD4841, DAD4941, Installation drawings

① The minimum dimension is required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used.

explanations

DAD4841, DAD4941, flush, Installation drawings

Side-by-side installation of the downdraft hood and the cooktop in a common cutout., Example: combination with KM 7697 FL or KM 7594 FL., Flush installation, 1) Cut-out for exhaust air duct in the cabinet base., 2) Ensure sufficient stability of the worktop., 3) Step milling for flush mounting in a worktop. Note the, the different milling widths for the hob and the downdraft. , Instead of a step milling, a 5.5 mm downwardly offset wooden strip can be installed (not included in the scope of delivery)., , Exhaust air connection ø 150 mm.

explanations

DAD4841, DAD4941, overlying, Installation drawings

Installation of the downdraft hood and cooktop in separate cutouts., Surface-mounted installation, 1) Cutout for exhaust air line in cabinet base., 2) Ensure sufficient stability of the worktop., Exhaust air connection ø150 mm

explanations

DAD4841, DAD4941, Installation drawings

explanations

DAD4840, DAD4940, DAD4841, DAD4941 - flush - side view - Installation drawings

① Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., ② Exhaust air connection Ø 150 millimetres.

explanations

DAD4840, DAD4940, DAD4841, DAD4941 - surface mounted, AP 600 mm - side view - Installation drawings

① Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., ② Exhaust air connection Ø 150 millimetres.

explanations

DAD4841, DAD4941, flush, Installation drawings

Side-by-side installation of the downdraft hood and the cooktop in a common cutout., Example: combination with KM 7697 FL or KM 7594 FL., Flush installation, 1) Cut-out for exhaust air duct in the cabinet base., 2) Ensure sufficient stability of the worktop., 3) Step milling for flush mounting in a worktop. Note the, the different milling widths for the hob and the downdraft. , Instead of a step milling, a 5.5 mm downwardly offset wooden strip can be installed (not included in the scope of delivery)., , Exhaust air connection ø 150 mm.

explanations

DAD4840, DAD4940, DAD4841, DAD4941 - surface mounted, AP 600 mm - side view - Installation drawings

① Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., ② Exhaust air connection Ø 150 millimetres.

explanations

DAD4841, Installation drawings

1. Stepped cutout for flush-fit installation in stone worktops (granite, marble)., 2. Ensure that materials are sufficiently stable., 3. Cut-out off-centre., Exhaust duct Ø 150 mm., * Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used.

explanations

DAD4841, DAD4941, flush - AP600 mm, common cutout, Installation drawings

① Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., ② Exhaust duct Ø 150 mm.

explanations

DAD4841, DAD4941, overlying - AP600 mm, Side view, Installation drawings

① Only required when flat ducting is laid under cabinets or the DUU 600 recirculation box is used., ② Exhaust duct Ø 150 mm.

explanations

DAD4841, DAD4941, flush, Installation drawings

Installation of the downdraft hood and cooktop in separate cutouts., Flush installation., 1) Cut-out for exhaust air duct in the cabinet base., 2) Ensure sufficient stability of the worktop., 3) Step milling for flush mounting in a countertop. Note the, the different milling widths for the hob and the downdraft. Instead of a step milling, a wooden strip offset 5.5 mm downwards can be installed as an alternative (not included in the scope of delivery)., , Exhaust air connection ø 150 mm.

explanations

DAD4840, DAD4940, DAD4841, DAD4941 - flush - side view - Installation drawings

① Only required if flat ducts are laid under the cabinets or the DUU 600 recirculation box is used., ② Exhaust air connection Ø 150 millimetres.

Image(s) as examples, to illustrate